Monthly Archives: March 2019

Improve Dental Mechanics

If the dentist uses dental BUR is because you need to do an implant, a Crown or a bridge. The development of an implant dental laboratory is very wasteful because it must fit perfectly to the patient. Phosphates are used as binding agents in the coating dental implants that acquire the required shape. Based on mold making by dentist denture is manufactured a dental model in plaster. The implant dental becomes first in wax and then elaborates with alloys such as gold, Platinum, or titanium. To manufacture the mold to make the alloy, the wax model is introduced into a mass composed of flour of quartz, cristobalite, magnesium oxide, Silicon sol and a binder based on phosphates. This binder reacts with magnesium oxide and hardening. Subsequently burns the mass at a temperature of 800 to 1000 centigrade.

The wax will melt thus creating a space in which the alloy is poured. Budeheim is one of the leading producers in the field of production of binders for masses of implants. FABUDENT, a fine powder of great quality, is a suitable Binder because it ensures rapid hardening and optimum stability of the shape without the need to expose it to additional heat. Finally, after all, the implant has to be adjusted as well to the patient as the original. This type of hand piece gives us the possibility of working at a right angle or angled so as shown in the image. The straight is very useful to perform work outside the oral cavity and the angled part allows us to work comfortably within the mouth, for example prophylaxis, polishing resins or amalgams and many more uses. Cave mention rotating instruments vary from the straight piece to conta-angled piece, the straight part uses some strawberries of greater length and are attached by friction; use in contra-angle are more short and at the end opposite to the active part take a Groove for the fixation system by click or bolt. With the advancement of electronics, appeared for several decades, small electric motors that rotate between 4,000 and 40,000 R.PM., and that adding them hand pieces and contra-angle handpieces multipliers or reducers, cover a range of 600 to 120,000 R.RM. In addition to the above there are contra-anguladas high-torque low-speed parts, these are used in implantology, where the bone without much friction must be drilled for not heated and not cause tissue necrosis, this also implies that they have additional cooling.

© 2011-2024 SiliconGroup.net All Rights Reserved